Get a quote

Do I need a permit for a business sign in Woodinville?

City of Woodinville, King County, Washington. Governing rules: Woodinville Municipal Code Chapter 21.44, Signs.

Checked November 2026

Short answer. Yes, for most business signs. In Woodinville, a sign permit is required to erect, install or replace any permanent sign larger than 2 sq ft, and any limited duration or portable sign larger than 4 sq ft (WMC 21.44.040). Smaller signs and a list of exempt signs, including window signs, do not need a permit but must still meet the code.

What needs a permit

  • A sign permit is required to erect, install or replace any permanent sign with a sign area greater than 2 sq ft, or any limited duration or portable sign greater than 4 sq ft (WMC 21.44.040(1)).
  • Signs that do not need a permit must still meet all other rules in the chapter, including size and number limits (WMC 21.44.040(4)).
  • Allowed without a permit: incidental signs of 2 sq ft or less, interior signs more than 3 feet from exterior windows, non-illuminated plaques and building nameplates up to 4 sq ft, address signs (up to 32 sq ft each in nonresidential zones), and flags, among others (WMC 21.44.040(5)). A commercial flag is limited to one per business and 20 sq ft.
  • Window signs are exempt from the permit requirement but may not cover more than 20 percent of the window area (WMC 21.44.060(4)).
  • A permit for a limited duration or portable sign is valid for one year and may be renewed annually (WMC 21.44.040(3)).

Key rules

  • Building signs in nonresidential zones (NB, TB, CBD, GB, O, T/I and I): one per tenant per building facade, no more than two per tenant, plus one building sign per building and one shingle sign per tenant up to 3 sq ft. Maximum sign face is 8 percent of the building facade area, which can rise to 12 percent under the large sign standards (Table 21.44.070(2), WMC 21.44.080).
  • Freestanding signs in nonresidential zones: one for each full 250 feet of street frontage, with at least one per street frontage. Sign area is 1 sq ft per 4 feet of frontage, minimum 25 sq ft and maximum 75 sq ft, and maximum height is 10 feet. Signs meeting the large sign conditions may reach 100 sq ft and 15 feet (Table 21.44.070(2), WMC 21.44.080). Freestanding signs must be set back at least 5 feet from street rights-of-way (WMC 21.44.060(2)).
  • Building signs may not rise above the roofline or a full-width parapet, and may not project more than 18 inches from the wall. Projecting signs may extend up to 5 feet from the wall, must stay at least 3 feet from the curb, and need 8 feet of clearance over walkways (WMC 21.44.050, 21.44.060(1)).
  • Illumination is allowed in nonresidential zones. External lights must be no farther from the sign than the height of the sign area, lighting must be shielded, no more than 0.2 footcandles may reach an abutting property, and all lighting must be static (WMC 21.44.050(8)).
  • Electronic changing message signs: only one per site, the digital display may not exceed 50 percent of the sign area or 32 sq ft, whichever is less, and each message must stay on at least 8 seconds. Digital displays are limited to 5,000 nits in daylight and 250 nits at night, with automatic dimming (WMC 21.44.050(8)(c), 21.44.060(3)).
  • Prohibited signs include billboards and other off-premises signs, flashing, strobe or scrolling signs except as permitted, reflective or mirrored signs, inflatable devices, balloon signs, pennant stringers, streamers and feather flags (except in temporary noncommercial situations), and signs in the public right-of-way except as allowed (WMC 21.44.030).

How to apply

  • A sign permit application must include a description of the sign showing number, size, shape, dimensions and colors, a site plan showing the sign location relative to nearby buildings and streets, and illumination information if the sign will be lit (WMC 21.44.040(2)).
  • For limited duration and portable signs, state how long the sign will be displayed (WMC 21.44.040(2)(b)).
  • Signs projecting over a city right-of-way need city permission for the projection (WMC 21.44.050(5)). Flagpoles and other support structures may need a building permit under Chapter 21.62 WMC.
  • Woodinville City Hall phone: 425-489-2700.

Lit signs and electrical permits

The City of Woodinville sign permit covers size, placement and appearance. Electrical work for a lit sign is a separate permit. Woodinville is not on the Washington State Department of Labor & Industries (L&I) list of cities that issue their own electrical permits, so electrical permits and inspections for illuminated signs go through L&I.

Sources

This page summarizes official City of Woodinville sources. Codes and fees change, so confirm with the city before you order or install a sign.