Get a quote

Do I need a permit for a business sign in Spokane?

City of Spokane, Spokane County, Washington. Governing rules: Spokane Municipal Code Chapter 17C.240, Signs.

Checked November 2026

Short answer. Yes. In Spokane, a city permit is required before a sign covered by the sign code is erected, structurally altered or relocated, unless the sign is listed as exempt (SMC 17C.240.090). Copy changes without structural change, painting and cleaning, and small informational signs are among the exemptions. Illuminated signs may also need a separate electrical permit.

What needs a permit

  • A City permit is required before any sign governed by the code is erected, structurally altered or relocated (SMC 17C.240.090).
  • Signs that already had permits and conformed to the code when it was adopted need no new permit unless they are later structurally altered or relocated (SMC 17C.240.090).
  • Exempt: painting, repainting or cleaning of a sign structure, and changing the advertising copy or message, unless a structural change is made (SMC 17C.240.060).
  • Exempt: "no trespassing", "no parking" and similar informational signs, including restroom and entrance signs, up to 3 sq ft each; and signs inside a building or an enclosed lobby or court meant to be seen by that use's patrons (SMC 17C.240.060).
  • Exempt: memorial signs or tablets, building names and erection dates cut into the surface or projecting no more than 2 inches (SMC 17C.240.060).

Key rules

  • Wall signs in CC2, CB and CA3 zones: 1-1/2 sq ft per 1 foot of primary building wall or 15 percent of the primary building wall, whichever is greater (SMC 17C.240.230).
  • Freestanding signs are allocated 1 sq ft per 1 foot of arterial street frontage; local street frontage can be used if the site has no arterial frontage (SMC 17C.240.230).
  • Electronic message center signs: each static image must display at least 2 seconds, flashing is prohibited, an automatic dimming photocell is required, and brightness may not rise more than 0.3 foot-candles over ambient light. They are not allowed in downtown zones or CC4, and are limited to the lesser of 50 percent of allowable sign area or 48 sq ft in CC2, CB, CA3, GC, LI and HI (SMC 17C.240.247).
  • Prohibited: flashing signs (unless they meet the electronic message rules), abandoned signs, permanent balloon signs, signs that resemble or interfere with traffic control devices, vehicles parked mainly to display signs, and signs that block required exits (SMC 17C.240.070).
  • Signs on or projecting over public streets, sidewalks or rights-of-way are prohibited, except awnings and marquees, sandwich boards and certain temporary signs allowed by the code (SMC 17C.240.070).

How to apply

  • Submit through the City's online permit system at aca.spokanepermits.org for the quickest review, or by email to [email protected].
  • In person: Development Services Center, Spokane City Hall, 3rd Floor, 808 W Spokane Falls Boulevard, Spokane, WA 99201. Phone (509) 625-6300.
  • Include a site plan, elevation plan and sign drawings. The code asks for a site plan showing the lot, buildings and all existing signs with their sizes and heights, the parcel number or address, and a scaled drawing of the sign with its size, height, copy, footing details, attachment method and illumination (SMC 17C.240.090, sign permit application).
  • Electronic message signs need a signed letter of compliance with the brightness limits (SMC 17C.240.247).
  • Fees are set by SMC 8.02.031(G) (SMC 17C.240.090). The application form lists a processing fee, sign review fee, State Building Code fee, technology fee and an illumination/wiring fee per sign.

Lit signs and electrical permits

The City of Spokane sign permit covers size, placement and appearance. Electrical work for a lit sign is a separate permit. The City of Spokane issues its own electrical permits and inspections inside city limits, per L&I's list of cities that do their own electrical work. The City's sign application says a separate electrical permit is required for a powered or illuminated sign when the applicant does not hold an electrical contractor's license.

Sources